随着绿色建筑概念的普及,在各个国家的建筑规范中,都增加了建筑节能的要求,虽然表述不同,但总体来说,就是通过增加墙体的保温性能,达到减少能量流失的目的。
在热工计算中,常用的有概念有热阻、导热系统等,凑个字数吧
Energy efficiency
节能
NCCENERGY EFFICIENCY DETAILS
NCC节能详细情况
Glossaryof terms
术语表
1. R-Value means the thermalresistance (M2.K/W) of a component calculated by dividing its thickness by itsthermal conductivity.
R值为通过物体导热系数除于其厚度得出的热阻(M2.K/W)
2. Renewable energycertificatemeans a certificate issued under the Commonwealth Government’s mandatoryrenewable energy target scheme.
可再生能源证书为在英联邦政府强制性可再生能源目标计划下颁发的证书。
3. TotalR-Valuemeans the sum of the R-Values of the individual component layers in a compositeelement including any building material, insulation material, airspace andassociated surface resistances.
总R值为在复合单元(包括任何建筑物件、保温材料、空气间层及关联表面电阻) 各个组成层的R值总和。
4. Total U-Value means the thermaltransmittance (w/2.k)ofthe composite element allowing for the effect of any airspace and associatedsurface resistances.
总U值为允许任何空气间层及相关表面电阻的复合原件的传热系数。
BuildingFabric
建筑构造
1.1 Roof
屋顶
All required insulation will be installed inaccordance with 3.12.11 building fabric thermalinsulation, the manufacturer’s specification, and AS/NZS 4859.1
所需绝缘必须按照3.12.11建筑结构热绝缘、制造商说明及澳标/新西兰标准4859.1安装。
1.2 Walls
墙体
All required insulation will be installed inaccordance with 3.12.1.1 building fabric thermalinsulation, the manufacturer’s specification, and AS/NZS 4859.1
所需绝缘3.12.1.1建筑构造必须按照建筑构造热绝缘,建造商说明及澳标/新西兰标准4859.1规定安装。
一个偶然的机会,在新西兰某品牌的热反射膜的产品手册中看到这个热工计算,当时是震惊的,这不是坑人吗
但查了一下国内的规范,居然是这样的
这是什么概念呢?
根据规范,封闭的空气层,在双面铝箔反射面的包裹下,R指是0.7。这个0.7是什么概念呢?
以AAC板参数为例,导热系数是0.1左右,0.7的热阻相当于70mm厚度的AAC板的热阻,因此,应充分利用。
总结,轻骨架建筑中空的结构是一种天生的保温层,应充分利用,目前铝箔贴面的卷材价格约为不足10元/㎡,也就是花费不足20元/平米,就可获取0.7的热阻值,非常划算。